On Windows 98 or Windows 2000, if SilkTest launches but will not fully exit after execution of tests (leaving a blinking "SilkTest" window on the task bar).

This is due to a problem with Windows. The directory "W98_2000" on your SilkTest installation CD includes a file that should prove helpful. To perform this fix manually, use RegEdit to modify the following key in the registry of the computer running SilkTest:

HKEY_CURRENT_USERControl PanelDesktop

"ForegroundLockTimeout"=dword:000003E8